Best Refrigerant Leak Detectors

Refrigerant Leak Detectors Sensitivity Warranty
LotFancy Freon Leak Detector 0.21 oz/year 1 year
Elitech Refrigerant Leak Detector 0.14 oz/year 3 years
Fieldpiece SRL2(K7) Refrigerant Leak Detector 0.18 oz/year 1 year
Robinair Refrigerant Leak Detector 3 adjustable levels 2 years

What Sniffer is considered the best sniffer available for R134A leak detection?

Most Versatile. Adjustable and highly sensitive, the Elitech Refrigerant Leak Detector is one handy diagnostic and detection tool. This device can pick up freon leaks and their triggers on all different types of refrigerants, including popular varieties like R22, R134A, R404A, and R410A.

What gases are safe to use for refrigerant system pressure testing?

Nitrogen (oxygen free / OFN) is the gas most commonly used to pressure test systems prior to refrigerant charge, or as part of servicing following refrigerant recovery….Nitrogen/Helium Mix

  • improved detection.
  • safe and easy to use, inert and non-flammable.
  • cost effective.

How does an electronic refrigerant leak detector work?

Infrared leak detection is a technology in which infrared light is applied to detect refrigerant. The refrigerant absorbs some of the infrared light, and the degree of change in refrigerant concentration is measured. This is a sensitive and accurate technology.

Can you test for Freon in the air?

Dye Testing Your air conditioning technician can add a special kind of dye to your AC unit, which works its way throughout the system. Then, using an ultraviolet light, your technician can see where the refrigerant has been leaking and address the issue.

What is the best visual indicator of a refrigerant leak?

If there is a leak, dye will come out with a bright yellow-green color to help you pinpoint where the leak is located. Typically, this also requires scanning the system with a blue light or UV lamp.

Which gas should not be used for leak testing in a refrigerant system?

Never use air or pure oxygen. Often, a refrigerant trace gas is introduced into a recovered and evacuated system along with the nitrogen. The trace gas enables electronic leak detectors to be used to detect the vicinity of the leak.

Why is dry nitrogen used in a pressure test instead of refrigerant?

Dry (oxygen free) nitrogen (OFN) is used to achieve the pressures required for the pressure tests because it is inert. You must never use oxygen for pressure testing – pure oxygen at high pressure reacts violently with oil and will explode.

What methods are commonly used to locate refrigerant leaks?

A technician can detect a refrigerant leak by using ultraviolet (UV) dye. An HVAC technician will send a fluorescent dye through your system to find the source of the leak. Once it circulates throughout your HVAC system, a detection lamp is used to find the leak’s exact location.

How do you check for refrigerant gas leaks?

7 Methods of Refrigerant Leak Detection

  1. Visual Inspection.
  2. Bubble Water or Soapy Water Detection.
  3. Nitrogen Water Detection.
  4. Fluorescent Leak Detection.
  5. Gas Pressure Detection.
  6. Halogen Lamp Detection.
  7. Electronic Leak Detector.

How do I find a leak in my AC refrigerant?

Here are a few ways HVAC professionals might identify leaks in your system.

  1. Soap bubbles. Soapy water applied to the suspected refrigerant leak will bubble up and give the location away.
  2. Ultraviolet (UV) dye. Dye is added to the refrigerant, and a special UV light is used to find leaks.
  3. Electronic leak detectors.